Manchester Piccadilly

cafe restaurant · North · 305 m² · 114,400 covers/yr
Open 7/7 days · typically 08:00–22:00

Consumption trend

March 2026 · half-hourly, with the overnight floor and occupied hours overlaid.

Active load Baseload (overnight floor) Occupied hours
01224kWh/interval1 Mar16 Mar31 Mar
Hover the chart for a half-hour's reading. Shaded bands are occupied hours; the dashed line is the overnight floor.

Monthly consumption

Electricity and gas over FY25/26.

Electricity Gas
0k23k46k040506070809101112010203
Hover a column for the month's split.

Half-hourly pattern

Every half-hour of the year. Horizontal banding low on the chart is overnight load that never switches off.

LowHigh (kWh per half-hour)
00:0006:0012:0018:0023:30AprMayJunJulAugSeptOctNovDecJanFebMar
Hover a cell for its value; each column is one day, each row a half-hour.

Findings at Manchester Piccadilly

Ranked by severity, then by annual cost. Every figure links to the data behind it.

Step change in consumption at Manchester Piccadilly

Load rose by 261% on 2025-11-12 and has stayed there — about £10,689 a year. A persistent step usually means a setting changed or new equipment was installed.

→ Confirm what changed on or around 2025-11-12.

CRITICALHigh confidence8.9 tCO2e/yrOpen evidence →q_0c52349e110b04b0
£10,689per year